1.4
Intended use
The pipe cleaning machines may only be used to clean pipes of the following diameters:
RODRUM S: 40-100mm
The pipe cleaning machines are only designed for short term operation and may therefore only
be operated without interruption for a maximum of 15 minutes! Do not use this product in any
other way as stated for normal use!
2
Technical Data
Voltage ........................................................... 230V, 50-60 Hz, 110-115V, 50-60Hz
Output P1/ P2 ................................................. 0,4 KW / 0,25 KW
Dimensions (L x W x H) .................................. 580 x 330 x 395 mm
Empty weight .................................................. about 15,5kg
Spiral type ...................................................... Ø 10mm and Ø 13mm
Max. spiral length in the drum ......................... 15m
Max. working length ........................................ 14,5m
Pipe diameter working range .......................... Ø 40-100mm
Speed of the spiral .......................................... about 6-7 m/min (according to the pipe route)
Direction of rotation (switch position I) ............. left (looking from the front onto the drum)
Protection class .............................................. I
Protection type ................................................ IP X4
Operating mode .............................................. S2 15min.
Vibration total value ........................................ < 2,5 m/s
Sound pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 61029-1:2010.
3
Scope of delivery
- Pipe cleaning machine.RODRUM S
- Guide tube
- Operating manual
- tool case (only for RODRUM S13)
4
Model plate description
Model No.
Item No.
Series No.
Production year
5
Power connection
Connect only to the single-phase alternating current indicated on the rating plate. Connect only
to sockets with protective contacts. The machine must be operated only through a ground fault
circuit with max. 30 mA rated leakage current.
Connection: Insert the device into an electrical socket and press the green "RESET" button.
14
) .............................. 79 dB (A) ¦ K
pA
) ................................. 90 dB (A) ¦ K
WA
ENGLISH
2
2
¦ K= 1,5 m/s
3 dB (A)
pA
3 dB (A)
WA
Rated voltage
Power consumption
Rated frequency
Protection class
Short-term operation 15min.