Continuity (
Range
Overload Protection: 600Vrms
Frequency (Hz)
Input
Current
Voltage
Overload Protection: 600Vrms or 600Arms
3.2
Digital Display:
3¾ digits LCD display, 4000-count (3999 max)
Analog Display:
Fast 42 segment analog bargraph display
Symbol and Scale Range:
Automatic according to range and input signal
Polarity:
displayed when negative signal applied to
input
Over Load:
displayed when input signal exceeds range
Sample Rate:
Quality AEMC Products Online at:
2 samples/sec for the digital display
20 samples/sec for the analog bargraph
Power Supply:
Two 1.5V AAA (LR03) alkaline batteries
TRMS Clamp-on Meter Model 502
)
Beeper Activation
< 40Ω
(Auto-ranging)
Range
20 to 4kHz
10kHz
10 to 4kHz
40kHz
400kHz
Mechanical Specifications
GlobalTestSupply
www.
Max Test Voltage
Res
Accuracy Sensitivity
1 Hz
0.1% Rdg
± 1ct
10 Hz
1 Hz
0.1% Rdg
10 Hz
± 1ct
100 Hz
.com
1.5V
DC
2Arms
5Vrms