Using the DC kit
8
Using the DC kit
The DC-Kit2 consists of several components, each with its own installation and
operating manual. Use the installation and operating manuals for the components
and make sure you are familiar with the individual devices.
This chapter contains information on operating the overall system. This operating
manual does not replace any information contained in the installation and operating
instructions for the components.
A
NOTICE!
CA2500, B2200, B1600 Plus, FJ1100, FJ1700, FJ2200, FL1600,
FL2200: the inverter may be damaged.
Ensure that these models are not used in the automatic air conditioning
mode or heating modes for driving. The inverter is not designed for gen-
erating this amount of power.
A
NOTICE!
CA2500, B2200, B1600 Plus, FJ1100, FJ1700, FJ2200, FL1600,
FL2200: the inverter may be damaged.
If you are operating the system on the 230 V mains and the automatic air
conditioner or the heating is on, make sure that the inverter is switched
off and stays switched off.
The inverter is not designed for the amount of power an active heating
system requires. If the 230 V mains power fails, the inverter would then
take over supplying the power.
I
NOTE
The operating noises made by the roof air conditioner are slightly louder
during mobile air conditioning than during stationary air conditioning.
The noises are caused by using the inverter.
20
DC-Kit2
EN