Faults, cause, remedy

Fault
Dräger X-zone 5000 cannot
be loaded.
Battery service life is low.
No wireless connection between the
Dräger X-zone 5000 devices.
Cable connection is not functioning. Cable plug is not correctly plugged
Alarm contact is not switching.
40
Cause
Charging unit plug is not in correct
contact with the Dräger X-zone
5000.
Battery is not fully charged.
Battery not regularly charged.
Outdoor temperature is too low.
Outdoor temperature is very high.
Battery is faulty.
Inductive charging is not functioning
correctly as the distance between
the Dräger X-zone 5000 and the
charging station is too great.
Wireless function is not activated.
Dräger X-zone 5000 devices are
very far apart.
The wireless connection is made
more difficult by an industrial
environment: e. g. steel walls.
Dräger X-zone 5000 are covered
by conductive materials
(e. g. metal grids).
Network number of the Dräger
X-zone 5000 devices is different.
Wireless frequency of the Dräger
X-zone 5000 devices is different.
in, cable assignment is incorrect or
cable is broken.
Cable plug is not correctly plugged
in, cable assignment is incorrect or
cable is broken.
Remedy
Ensure that the charging unit plug
is correctly plugged in.
Check the battery LED.
Load battery for at least 8 h - 12 Ah,
14 h - 24 Ah.
Charge battery regularly even when
switched off, at least every
2 months.
Warm up Dräger X-zone 5000.
Use safety housing where
appropriate.
Have the battery checked by
Dräger.
Check the distance, remove any dirt
if necessary.
Activate the wireless function using
the Dräger CC-Vision PC software
(refer to "Configuring the device" on
page 39).
Position the Dräger X-zone 5000
devices more closely together.
Position additional devices in the
chain.
Place Dräger X-zone 5000 at
a higher position, use base (order
no. 83 20 645) where appropriate.
Position the Dräger X-zone 5000
devices more closely together.
Position additional devices in the
chain.
Connect the Dräger X-zone 5000
with a communication cable (refer to
"Connecting devices via a cable
connection" on page 34).
Ensure there are no obstructions.
Use Dräger X-zone 5000 devices
with the same network numbers.
The network number can be
configured using the Dräger CC-
Vision PC software (refer to
"Configuring the device" on
page 39).
Use Dräger X-zone 5000 devices
with the same wireless frequency.
Check cable connection and
assignment. Ensure that the cable
plug is correctly plugged in.
Check cable connection and
assignment. Ensure that the cable
plug is correctly plugged in.