Warranty
The LED (fig. 2 2) indicates the fault:
LED display
Cause
Quick flash
Input voltage is too high Check the input voltage and reduce it.
Input voltage too low
2 s lit, short
Overheating
interruption
Excessive load
Off
Other fault
13
Warranty
The statutory warranty period applies. If the product is defective, please contact the
manufacturer's branch in your country (see the back of the instruction manual for the
addresses) or your retailer.
For repair and warranty processing, please include the following documents when
you send in the device:
• A copy of the receipt with purchasing date
• A reason for the claim or description of the fault
22
Remedy
The battery needs recharging.
Check the cables and connections.
Switch off the inverter and the consumer.
Wait 5 to 10 minutes and switch the inverter
on again without any electric consumers.
Reduce the load and make sure the inverter
has better ventilation. Then switch the
consumer back on.
Switch off the inverter and remove the
consumer.
Then switch the inverter back on without the
consumer. If no excessive load is now shown,
then there is a short circuit in the consumer or
the total load was higher than the power
specified on the data sheet.
Check the cables and connections.
Press in the fuse in the device again by hand.
Contact the service.
SinePower