ENGLISH
Battery packs with different capacities. Buy
battery packs only with voltage suitable for your
power tool.
Order no.: 6.25406 ....2.0 Ah
Order no.: 6.25349 ....4.0 Ah
etc.
Conversion kit 400 ml Order no.: (315418210
343444950)
Comprising a short toothed rod (6) and 400 ml tube
(3) for replacing parts.
Conversion kit 600 ml Order no.: (315418070
343444960)
Comprising a short toothed rod (6) and 600 ml tube
(3) for replacing parts.
Installation instructions for conversion kit:
See page 2, fig. C.
- Unscrew the tube (3).
- Extract the screw from the rod knob (7) and pull
the rod knob (7) back from the rod (6).
- Pull the toothed rod forwards from the motor
housing.
- Extract the screw and dismantle the components
(15) to (16) from the rod.
- Insert the rod from the conversion kit towards the
front.
- Attach the rod knob (7) on top and fasten it in
place with a screw.
- Fit components (15) to (16) on the other rod and
fasten in place with a screw.
- Screw the tube from the conversion kit together
tightly.
For a complete range of accessories, see
www.metabo.com or the catalogue.
9. Repairs
Repairs to electrical tools must ONLY be
carried out by qualified electricians!
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. See
www.metabo.com for addresses.
You can download a list of spare parts from
www.metabo.com.

10. Environmental Protection

Observe national regulations on environmentally
compatible disposal and on the recycling of disused
tools, packaging and accessories.
Battery packs may not be disposed of with regular
waste. Return faulty or used battery packs to your
Metabo dealer!
Do not allow battery packs to come into contact with
water!
Only for EU countries: never dispose of
power tools in your household waste! Used
power tools must be collected separately and
handed in for environmentally compatible recycling
in accordance with European Directive 2012/19/EU
on waste electrical and electronic equipment and its
implementation in national legal systems.
Discharge the battery pack in the power tool before
10
disposal. Prevent the contacts from short-circuiting
(e.g. by protecting them with adhesive tape).

11. Technical Data

Explanatory notes on the specifications on page 3.
+
Changes due to technological progress reserved.
U
= voltage
(max. voltage = 12 V,
nominal voltage = 10.8 V)
+
v
= Feed rate
F
= Extrusion force
m
= Weight (with the smallest battery pack)
Measured values determined in conformity with
EN 62841.
Permitted ambient temperature during operation:
-20 °C (-4°F) to 50 °C (120°F) (limited performance
with temperatures below 0 °C (32°F)). Permitted
ambient temperature for storage: 0 °C (32°F) to
30 °C (86°F).
Direct current
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. The actual load may be higher
or lower depending on the operating conditions, the
condition of the power tool or the accessories.
Please allow for breaks and periods when the load
is lower for assessment purposes. Arrange
protective measures for the user, such as
organisational measures based on the adjusted
estimates.
Vibration total value (vector sum of three directions)
determined in accordance with EN 62841:
a
= vibration emission value
h
K
= uncertainty (vibration)
h
Typical A-weighted sound levels:
L
= Sound-pressure level
pA
L
= Acoustic power level
WA
K
, K
=Uncertainty
pA
WA
Wear ear protectors!