Startup; Check Connections; Turning On The System; Check Output Values - Balluff BTL5-A -M -B-NEX-S32 Serie Manual De Instrucciones

Transductor de desplazamiento micropulse. forma constructiva de varilla.
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

BTL5-A/C/E/G1_-M_ _ _ _-B/Z-NEX-S32/KA_ _
Micropulse Linear Transducer - Rod Style
5

Startup

5.1

Check connections

Although the connections are polar-
ity reversal protected, components
can be damaged by improper con-
nections and overvoltage. Before
you apply power, check the connec-
tions carefully.
5.2

Turning on the system

Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no haz-
ards could result from these situa-
tions.
6

Versions (indicated on product label)

Supply voltage
BTL5-A11-M0450-B-NEX-S32
Nom. length (4digits): M = metric in mm
Analog interface:
5.3

Check output values

After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end position
of the magnet in manual mode. If
values other* than those present
before the replacement or repair are
found, a correction should be made.
* Transducers are subject to modifi-
cation or manufacturing tolerances.
5.4

Check functionality

The functionality of the transducer
system and all its associated com-
ponents should be regularly
checked and recorded.
1 = DC 24 V
:
Electr. connection
,
Rod Style
,
Mounting
B = metric thread M18×1.5
:
Z = thread 3/4"-16UNF
Voltage output A11 = 10 ... 0 V and 0 ... 10 V
G11 = 10 ... –10 V and –10 ... 10 V
Current output C10 = 0 ... 20 mA
C17 = 20 ... 0 mA
S32: with connector,
KA05: with 5 m cable
E10 = 4 ... 20 mA
E17 = 20 ... 4 mA
Ignition Class "n"
5.5

Fault conditions

When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
5.6

Maintenance

Repairs to the transducer must be
performed only by the service de-
partment of Balluff GmbH.