BTL5-A/C/E/G1_-M_ _ _ _-B/Z-NEX-S32/KA_ _
Micropulse Linear Transducer - Rod Style
5
Startup
5.1
Check connections
Although the connections are polar-
ity reversal protected, components
can be damaged by improper con-
nections and overvoltage. Before
you apply power, check the connec-
tions carefully.
5.2
Turning on the system
Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no haz-
ards could result from these situa-
tions.
6
Versions (indicated on product label)
Supply voltage
BTL5-A11-M0450-B-NEX-S32
Nom. length (4digits): M = metric in mm
Analog interface:
5.3
Check output values
After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end position
of the magnet in manual mode. If
values other* than those present
before the replacement or repair are
found, a correction should be made.
* Transducers are subject to modifi-
cation or manufacturing tolerances.
5.4
Check functionality
The functionality of the transducer
system and all its associated com-
ponents should be regularly
checked and recorded.
1 = DC 24 V
:
Electr. connection
,
Rod Style
,
Mounting
B = metric thread M18×1.5
:
Z = thread 3/4"-16UNF
Voltage output A11 = 10 ... 0 V and 0 ... 10 V
G11 = 10 ... –10 V and –10 ... 10 V
Current output C10 = 0 ... 20 mA
C17 = 20 ... 0 mA
S32: with connector,
KA05: with 5 m cable
E10 = 4 ... 20 mA
E17 = 20 ... 4 mA
Ignition Class "n"
5.5
Fault conditions
When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
5.6
Maintenance
Repairs to the transducer must be
performed only by the service de-
partment of Balluff GmbH.
english
7