2
Preset
temperature
for cooling
Preset
temperature
for heating
Settable preset temperature range
Operation mode
Cool/Dry
Heat
Auto (Single set point)
Auto (Dual set points)
Fan/Ventilation
The settable temperature range varies with the model of indoor units.
Press the
temperature, and press the
Refer to the table below for the settable temperature
range for different operation modes.
The preset temperature settings for cooling and heating in
the Auto (dual set point) mode are also used by the Cool/
Dry and Heat modes.
The preset temperatures for cooling and heating in the
Auto (dual set point) mode must meet the conditions
below:
Preset cooling temperature is higher than preset heating temperature.
The minimum temperature difference requirement between cooling and
heating preset temperatures (varies with the models of indoor units
connected) is met.
If preset temperatures are set in a way that does not meet the minimum
temperature difference requirement, both preset temperatures will
automatically be changed within the allowable setting ranges.
Preset temperature range
19 ~ 30 ºC (67 ~ 87 ºF)
17 ~ 28 ºC (63 ~ 83 ºF)
19 ~ 28 ºC (67 ~ 83 ºF)
[C ool]
Preset temperature range for the Cool mode
[H eat]
Preset temperature range for the Heat mode
Not settable
button to decrease the selected
button to increase.