IND780 Installation Manual
3. Repeat Step 2 for the other slot, freeing the bottom of the cover from the spring
retaining clips.
4. Once the panel is released, lift the bottom of the panel firmly up and out until it
clears the edge of the enclosure.
5. Press down on the top of the front panel and push the panel upward, relative
to the enclosure, until the spring retaining clips unsnap. The cover will then be
free to swing down, hinged by two wire cables at its bottom edge.
Mounting the Terminal
The Panel Mount enclosure is designed to mount into a cutout of a flat surface
such as an instrument panel or industrial enclosure or door. The harsh enclosure
is designed to be placed on a desktop or can be mounted to a vertical surface with
the optional mounting brackets. Mount the terminal where viewing is optimal and
the terminal keypad is easily accessible. Observe location and environment
considerations as described in Chapter 1.0, Introduction.
Panel Mount Enclosure
The Panel Mount enclosure comes with a gasket and a backing plate, used to
mount the unit to a panel. The enclosure will mount and seal properly on panel
thicknesses from 16 GA to 11 GA (1.52 mm to 3.04 mm).
Install the Panel Mount enclosure by following these steps:
Cut an opening and holes in the panel or industrial enclosure as indicated in the
panel cutout dimensions shown in Figure 2-3 in inches and [mm].
2-4
Figure 2-3: Panel Cutout Dimensions