IND780 Installation Manual
Harsh Enclosure Cable Glands and Cable
Assignments
Harsh Enclosure Cable Openings
Figure 2-21 and Table 2-1 show the uses and cable size limits of the various
openings in the back of the harsh enclosure. The pattern code is included for ease
of reference.
Pattern
2-14
Ethernet/PDX
USB/Ethernet
Scale 1
PLC 1
PLC 2
COM
Figure 2-21: Harsh Enclosure Cable Opening Assignments
Table 2-1: Harsh Enclosure Cable Openings
Description/Use
USB and Ethernet connections. 25 mm plastic cable gland
PDX, 25 mm metal cable gland
Analog Load Cell, 16 mm metal cable gland
POWERCELL, 16 mm metal cable gland
Scales 1-4, IDNet (proprietary connector)
Discrete I/O and Serial cables. 16 mm plastic cable gland 0.16–0.32 [4–8]
A-B Rio / PROFIBUS connectors – one in, one out
COM1 or COM2
Fourth scale connector or, with insert, COM2
Option 2
Scale 2
Scale 3
Scale 4
Option 1
A/C
Cable Size Limits
inches and [mm]
0.20–0.43 [5–11]
0.51–0.71 [13–18]
0.51-0.63 [13-16]
0.24–0.31 [6–8]
0.31–0.39 [8–10]
N/A
N/A
0.16–0.32 [4–8]
0.16–0.32 [4–8]