TROUBLESHOOTING
display
malfunctioning
Displays do not
The card is not powered up.
come on
Err 1
Err 1 appears on power-up
Err 2
During the measuring cycle the Err 2 message appears.
Err 3
During the measuring cycle the Err 3 message appears.
Err 4
The motor does not turn (with START pressed) or after about 20 sec. the Err
4 message appears.
Err 5
At end of second calibrating run with the wheel Err 5 appears on the display.
Err 6
Message Err 6 appears when pressing the START key.
Err 7
At end of second calibrating run with the wheel Err 7 appears on the display
Err 8
At end of second calibrating run with the wheel Err 8 appears on the display
Err 9
At end of second calibrating run with the wheel Err 9 appears on the display
Err 10
During launch Err 10 appears on the display.
Err 11
During launch Err 11 appears on the display.
Err 17
At end of launch Err 17 appears on display
Err 20
During measuring cycle Err 20 appears on display: the wheel speed has
gone below the minimum for measurability.
Err 21
During measuring cycle Err 21 appears on display: possible electrical fault.
Err 22
During the launch Err 22 appears on display
EEE EEE
EEE EEE appears on the display
Any other faults are largely technical in nature and must be checked and resolved by PROFESSIONALLY QUALIFIED PERSONNEL.
ENGLISH
Causes
1.
External supply off or phase not working.
2.
Fuse blown in the electrical plant.
3.
Control panel fuse blown.
1.
The card has lost the calibration data and factory configuration setting.
2.
One or more calibration or setting phases have not been carried out.
1.
The guard has been raised before completion of measurements.
1.
On start-up (using START key or lowering guard) the wheel was rotating backwards
2.
Motor winding inverted.
1.
The motor cannot reach the revolutions needed for effective balancing
2.
electronic card malfunctioning
3.
electrical plant malfunctioning
1.
Calibration weight has not been applied on the wheel.
2.
The pick-ups have not been connected
1.
The guard has not been lowered.
2.
Guard microswitch broken
1.
Phase difference between the 2 pick-ups is too large.
1.
The left pick-up has not been correctly connected or is defective or the cable is disconnected.
1.
The right pick-up has not been correctly connected or is defective or the cable is disconnected.
1.
Position sensors in optoelectronics defective.
2.
The motor will not turn
1.
Passage through zero sensor defective in optoelectronics
2.
The motor will not turn
1.
Weight out of regulation field (weight necessary for balancing the wheel is above 250 grams)
1.
1 Brake pedal operated during the measurement
2.
Motor rotation speed irregular.
1.
The electronic card has found a condition of danger connected to a too-high wheel speed during an
inactive machine phase (the shaft rotates at high speed without the operator having pressed the START
command); the electric power is deactivated.
1.
Some fault in the optoelectronic signals.
1.
Two keys pressed together.
2.
Keyboard defective.
COD. 653604 Rev.0
Trouble-shooting
1.
Check that positive/negative and neutral are connected up to balancer.
2.
Replace fuses in electrical plant (blown fuses indicate fault in electric plant)
3.
Replace fuses on control panel (blown fuses indicate fault in electronic part).
1.
Repeat all calibration and balancer configuration stages
2.
Perform missing programming or setting operations.
1.
Wait for end of measuring launch before raising guard.
1.
Ascertain that the wheel is still before start-up and in any case avoid rotating wheel
backwards on START.
2.
Check for correct motor connection.
1.
Check mains voltage (it is probably low)
2.
Replace electronic card
3.
Replace electrical part
1.
Repeat calibration from beginning and apply the calibration weight when instructed in the
calibration procedure (also see "Basic Machine Calibration")
2.
Check pick-up connections.
1.
Lower guard with wheel mounted.
2.
Replace microswitch.
1.
a) check that the calibration weight has been correctly applied;
b) also check machine location; it is probably not stable and is vibrating excessively;
c) if the problem persists after having stabilised the machine correctly, check the sensor and
electronic card connections (and replace if necessary);
d) replace pick-ups;
e) if after replacing pick-ups the problem is not solved, replace the card.
1.
Check left pick-up connection (and replace if necessary).
1.
Check right pick-up connection (and replace if necessary).
1.
a) check optoelectronic card connection.
b) check the optoelectronic card is protected from daylight and cover if necessary;
c) if the defect persists check and if necessary replace the optoelectronic card.
2.
Check electrical part.
1.
a) check optoelectronic card connection.
b) check the optoelectronic card is protected from daylight and cover if necessary;
c) if the defect persists check and if necessary replace the optoelectronic card.
2.
Check electrical part.
1.
a) Check that the wheel is correctly fixed on the flange;
b) find (in any case) the external position, apply a 100 gram weight and launch a run..
1.
Avoid pressing the brake pedal when the motor is operating.
2.
beware of knocking the machine during the measuring cycle. check mains voltage (probably
low)
1.
Switch off the machine, lower the guard and switch the machine back on without moving the
wheel; if the error persists, check (and replace if necessary) the electric or electronic part
(control panel or encoder card).
1.
a) check the optoelectronic card is protected from daylight and cover if necessary;
b) if the defect persists check and if necessary replace the optoelectronic card.
c) check and if necessary replace the control panel electronic card.
1.
Press one key at a time
2.
Check and if necessary substitute the control panel electronic card.