asberprofessional.com
15.2 Errors shown in display.
The following table lists the error warnings that may be displayed.
ER‐
RORS
ON/OFF LED lights up for 0.5 s and turns off for 2
E1
seconds, repeatedly.
ON/OFF LED lights up twice for 0.5 s each time
E2
and turns off for 2 seconds, repeatedly.
ON/OFF LED lights up three times for 0.5 s each
E3
time and turns off for 2 seconds, repeatedly.
ON/OFF LED lights up four times for 0.5 s each
E4
time and turns off for 2 seconds, repeatedly.
ON/OFF LED lights up five times for 0.5 s each
E5
time and turns off for 2 seconds, repeatedly.
51
asberprofessional.com
DETECTION
DENOMINATION
Door or hood is open.
Incorrect water level. Stipulated fill time
exceeded.
Incorrect drainage of the machine Stipulated
drainage time exceeded.
Incorrect boiler temperature. Stipulated
boiler heating time exceeded.
Incorrect tank temperature. Stipulated tank
heating time exceeded.
ENGLISH