system zone as the switchboard 1083/40, the interface allows, by pressing a function button of 1083/40,
to transfer the calls directed to the switchboard to the telephone connected to the interface on the
telephone output au, bu.
LINE TERMINATION SETTING
On the interface there is a jumper which allows to insert the line termination. The termination must be
activated in all the devices installed at the end of a line that does not start again with another segment from
the terminal pins LINE OUT:
LINE OUT
LINE 3
1083/55
LINE 4
LINE IN
CONFIGURATION IN APARTMENT STATION MODE
CODE: user code.
§
Set the Dip 1 CODE in OFF position.
Set a number from 0 to 63, according to the following rules:
•
In the column there must not be any apartments with the same user code.
•
If there are apartment stations in parallel in the same apartment, these must have the same user code.
•
The user codes of the same column must be consecutive.
§
To set the desired code, use the dip switches from 2 to 8 (2= most significant bit - 8= less significant
bit); the dip-switch 1 must be set to OFF.
The table with the positions of dip-switch for each code is in the system manual provided with the
power supply 1083/20.
INT:
apartment internal code.
Set a number from 0 to 3, according to the following rules:
•
If in the apartment there is only one station, the internal code must be set to 0.
DS1083-01A
LINE OUT
LINE IN
LINE 1
LINE 2
Line Termination
ON
Termination
Termination
ON
ON
Termination
OFF
OFF
Termination
ON
LINE OUT
LINE 3
LINE 1
1083/55
LINE 4
LINE 2
LINE IN
9