Installing The Indoor Unit - Mitsubishi Electric CITY MULTI PMFY-P06NBMU-E Manual De Instalación

Ocultar thumbs Ver también para CITY MULTI PMFY-P06NBMU-E:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2. Installing the indoor unit

Fig. 2-1
Fig. 2-2
39-3/8 (1000)
37-13/16 (960)
13/16 (20)
31-15/18 (811)
2-15/18 (74.5)
1-1/32 (26)
29-7/8 (759)
13/16 (20)
Fig. 2-3
in. (mm)
in. (mm)
13/16 (20)
2-15/18 (74.5)
1-1/32 (26)
13/16 (20)
2-1/16(53)
2.1. Check the indoor unit accessories (Fig. 2-1)
The indoor unit should be supplied with the following spare parts and ac-
cessories
(contained in the inside of the intake grille).
Accessory name
1
Washer
Washer (with insulation)
2
Pipe cover
3
Band
4
Screw
5
Glass tube
6
7
Plate for conduit
8
Drain socket
9
Insulation
2.2. Service space (Fig. 2-2)
• The dimensions of ceiling opening can be regulated within the range shown in
following diagram; so center the main unit against the opening of ceiling, ensur-
ing that the respective opposite sides on all sides of the clearance between them
becomes identical.
Air intake
A
Air outlet
B
Ceiling panel
C
Min. 7-7/8 in. (200 mm)
D
Suspension bolts W3/8 or M10
E
Grille
F
2.3. Ceiling openings and suspension bolt installation
locations (Fig. 2-3)
• Make an opening in the ceiling 17 in. × 37-7/8 in. (430 mm × 960 mm) in size.
This functions as a check window and will be needed later during servicing.
• If the dimensions are not accurate, when the grille is installed there may be gaps
between it and the indoor unit. This may result in dripping water or other problems.
• When deciding on placement, consider carefully the space around the ceiling and
make your measurements generous.
• Ceiling types and building construction differ. Therefore you should consult with
the builder and decorator.
The centers of the ceiling opening and the indoor unit should be aligned.
A
Outer side of grille
1
Ceiling opening
2
Bolt pitch
3
Electric box
4
• Using the installation template (top of the package) and the gauge (supplied as
an accessory with the grille), make an opening in the ceiling so that the main unit
can be installed as shown in the diagram. (The method for using the template
and the gauge are shown.)
• Use M10 (3/8") suspension bolts.
* Suspension bolts are to be procured at the fi eld.
• After suspending the indoor unit, you will have to connect the pipes and wiring
above the ceiling. Once the location has been fi xed and the direction of the pipes
has been determined, place the refrigerant and drainage pipes, the wiring for the
remote controller, and the wiring that connects the indoor and outdoor units in
their desired locations before suspending the indoor unit. This is especially im-
portant in cases where the ceiling is already in existence.
Q'ty
4 pcs
4 pcs
2 pcs
6 pcs (Long)
2 pcs (Middle)
2 pcs (Short)
4 pcs M5 × 0.8 × 30
2pcs M4 × 12
1 pc
1 pc
1 pc Marked with "UNIT"
1 pc
3

Capítulos

Tabla de contenido
loading

Tabla de contenido