ALAr
It's not find
Fan
the rotation
FAiL
of the
exhaust
fume motor.
ALAr
It's not find
no
the fire on
FirE
foyer.
ALAr
The fumes
temperature
Hot
tEMP
is too high
(over the
alarm
value).
ALAr
Noticed the
rupture of
Sond
Fumi
the fume
feeler
Foyer
CooL
cooling.
FirE
ON
The
temperature
1...5
in the room
on t
is not found
In case of glow plug breaking, waiting for repair, it's possible to push the
ALAr
no Acc
ignition button for a manual ignition employing a small cube of firelighter.
Every intervention has be done from qualify staff !
Disconnect the equipment from electrical system before every maintenance operation
Every repairs must be done by our authorized assistance centre.
CORISIT S.r.l. is not responsible for damages to thing or people due to a wrong installation,
equipment tampering, improper use, bad maintenance or no observation of normative in
force. If considerate appropriate, CORISIT S.r.l. reserves the right to make modifications
without notice and in every moment.
Some particulars and accessories illustrated in this handbook are not mass produced item so
its extra costs are to check at contract release.
− Electrical connection break
off.
− Motor breaking.
No Pellets feed.
− Exit air convection is
blocked.
− Convection motor breaking.
− Wrong position fumes feeler.
− Electrical connections
interrupted
− Rupture of the feeler
− Tension break off.
−
The environment feeler is
broken
55/112
IT-GB-FR-ES mod. 515S-515N
− Check feed motor connection
and encoder connection.
− Substitute motor.
− Check Pellets tank level.
− Check screw feeder function.
− Possible screw feeder
obstruction.
− Check air convection intake.
− Check convection motor
function.
− The fumes feeler is inserted too
deeply.
− Verify the correct connection
of the feeler
− Change the fume feeler
− Wait for the automatic ignition.
−
Check the environment
−
Substitute the environment
feeler.
feeler.
.