Lstove Use On Manual Modality; Equipment Turning Off - Lincar Milly 515S Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

H
To carry out the following program Ignition / Turning Off go on as points E-F-G. See
table 1 to identify the correspondent data ut08-ut09-ut10, ut11-ut12-ut13, ut14-ut15-
ut16 (vedi tabella "Cronotermostato").
Attention !! To go out program, push the button 4 in every point.
I
Attention to possible overlapping about ignition / turning off program's hour; a wrong
program means that the stove will start / turn off when it's necessary that it's light on
(or the contrary) so we recommend to not program in the same day new ignition before
the turning off hour of precedent cycle.
Program 1°
cycle
Program 3° cycle
Functioning
Effective function due to programs overlapping
STOVE USE ON MANUAL MODALITY
L
It's possible to carry out manual Ignition/ Turning Off even with active programs which will
start up and turn off during predetermined hour at the same. To use the stove only on manual
modality, go on as point L.
It's possible to have the equipment that start to a set hour but the switching off is depending
on user : to have this program, set the time of switch off (point F) on value OFF, any
switching off time is selected and the user will decide the equipment switch off, pushing the
button 4 (start/turn off).
On the contrary, the equipment could not have a time of ignition but a set hour to switch off :
to have this program, set the start hour (point E) on value OFF, so any start time will be
present and the user could light up the equipment when he wants, pushing the button 4
(start/turn off), when the switch off time is reached, the equipment will switch off
automatically.

EQUIPMENT TURNING OFF

Pushing for several time the button nr. 4 on control panel, the turning off operation start
up, the screw feeder motor is deactivated and the pellets is no more feed. The two fans (
gas combustion fan and fan for air convection ) will function again for some minutes till
the exhaust gas temperature lower then they turn of.
To employ the stove on manual modality without delete the recorded
program, go on as point B and program ut01 – oFF .
To active again all programs to select ut01 and the current day.
IT-GB-FR-ES mod. 515S-515N
Program 2°cycle
Program
4° cycle
Funct.
Funct.
48/112
Saturday
Saturday

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Luna 515nStella 730Stella 730 ecoAriel 730nf

Tabla de contenido