Adjusting The Nailing Depth; Changing The Exhaust Direction; Cutting Off The Sheet - Hitachi Koki NV 75AG Instrucciones Y Manual De Seguridad

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

result if the push lever accidentally contacts you
or others in work area.
Keep hands and body away from the discharge
area. The nailer with contact trip mechanism may
bounce from the recoil of driving a fastener and
unwanted subsequent fastener may be driven,
possibly causing injury.
Some types of loaded nails can spark out of the
muzzle during a nail driving operation. Exericise
caution!
The OPTIONAL SEQUENTIAL TRIP MECHANISM (SINGLE
SHOT PARTS) is for use where precision fastener
placement is desired and must be operated in accordance
with the following "Method of Operation".
You must first depress the push lever (upward
position) where you want to drive a nail and then pull
the trigger.
After the each nail is driven, completely release the
trigger and lift the tool off the work surface.
An OPTIONAL SEQUENTIAL TRIP MECHANISM may
reduse the possibility of bodily injury to you or others
in the work area. This is because it is less likely to
drive an unwanted nail if you keep the trigger pulled
and accidentally bump the push lever against yourself
or others. An OPTIONAL SEQUENTIAL TRIP
MECHANISM may also reduse the speed of operation
compared to the standard contact trip mechanism.
NOTE:
Both STANDARD CONTACT TRIP MECHANISM and
OPTIONAL SEQUENTIAL TRIP MECHANISM are safe if
used as described above and according to all
warnings and instructions.
Always handle nails and package carefully.
If dropped, the collated nails may break or come
loose. In such cases, do not use the nails because, if
used in that condition, nail feed may become faulty
and result in missed nails or jamming of the nails.
After nailing:
1) disconnect air hose from the Nailer;
2) remove all nails from the Nailer;
3) supply 5 – 10 drops of Hitachi pneumatic tool
lubricant into the air plug on the Nailer; and
4) open the petcock on the air compressor tank to
drain any moisture.

ADJUSTING THE NAILING DEPTH

To assure that each nail penetrates to the same depth, be
sure that:
1) the air pressure to the Nailer remains constant
(regulator is installed and working properly), and
2) the Nailer is always held firmly against the workpiece.
If nails are driven too deep or shallow into the workpiece,
adjust the nailing in the following order.
1 DISCONNECT AIR HOSE FROM NAILER.
2 If nails are driven too deep, turn the adjuster to the
shallow side.
If nails are driven too shallow, turn the adjuster to the
deep side.
Flush
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTOR.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
CHANGING THE EXHAUST
DIRECTION
The direction of the exhaust vent can be changed by
turning the top cover.
Exhaust
Vent

CUTTING OFF THE SHEET

Tear off the output sheet in the direction of the arrow
when using the sheet collated nails.
Sheet
— 15 —
(
)
Shallow
(
)
Deep
Adjuster
Too deep
Too shallow
Top Cover
English
Tabla de contenido
loading