ADJUSTING AIR PRESSURE

Adjust the air pressure at recommended operating pressure 70 – 120 psi (4.9 – 8.3 bar 5 –
2
8.5 kgf/cm
) according to the length of nails and the hardness of workpiece.
The correct air pressure is the lowest pressure which will do the job. Using the Nailer at a
higher than required air pressure unnecessarily over stresses the Nailer.

LOADING NAILS

● When loading nails into Nailer,
1) do not pull trigger;
2) do not depress push lever; and
3) keep Nailer pointed downward.
(1) 1 Raise the magazine stopper lightly
and pull the lever.
2 Pull the magazine (B) out.
(2) Set nail strip into the magazine (A) and
keep the points of nails in contact with
Groove.
WARNING
● Do not exceed 120 psi
(8.3 bar 8.5 kgf/cm
WARNING
Magazine (B)
Lever
Nail Strip
Magazine (A)
English
2
).
Magazine Stopper
Groove