7.6
Brands and types of oils recommended
The pump is supplied with oil of a type suitable for room
temperatures from 0°C to 30°C.
Some types of recommended oil are indicated in the table
below. These oils have additives to increase corrosion
resistance and fatigue resistance (DIN 51517 part 2).
Alternatively you can use Automotive Gear SAE 85W-90 oil for
gearing lubrication.
Manufacturer
Lubricant
AGIP ACER220
Aral Degol BG 220
BP Energol HLP 220
CASTROL HYSPIN VG 220
CASTROL MAGNA 220
Falcon CL220
ELF POLYTELIS 220
REDUCTELF SP 220
NUTO 220
TERESSO 220
FINA CIRKAN 220
RENOLIN 212
RENOLIN DTA 220
Mobil DTE Oil BB
Shell Tellus Öl C 220
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
Manufacturer
Lubricant
TOTAL Cortis 220
Check the oil level via the plug with the oil dipstick that has
minimum and maximum marks , Fig. 3. Top up to restore the
level if necessary.
The correct checking of the oil level is made with the pump at
ambient temperature.
The oil should be changed with the pump at working
temperature by removing the plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
chapter 11.
The necessary quantity is ~8.5 litres for pumps with a
reduction unit and ~7.5 litres for pumps with no reduction
unit.
In any case the oil must be changed at least once
a year, as it is degraded by oxidation.
For a room temperature other than between 0°C - 30°C, follow
the instructions in the following diagram, considering that oil
must have a minimum viscosity of 180 cSt.
48