2.12 Using extension cords

Use only extension cords of a type approved for the application and with conductors of adequate cross section. The
power tool may otherwise loose performance and the extension cord may overheat. Check the extension cord for
damage at regular intervals. Replace damaged extension cords.
Recommended minimum conductor cross section and max. cable lengths
en
Conductor cross section
Mains voltage 110-120 V
Do not use extension cords with 16 AWG conductor cross section.
2.13 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this application.
2.14 Using a generator or transformer
This tool may be powered by a generator or transformer when the following conditions are fulfilled: AC voltage and
power output of at least 2,600 W, operating voltage must be within +5% and -15% of the rated voltage at all times,
frequency must be in the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic
voltage regulation and starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching other
power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the
power tool.

3 Insert tools, accessories

Insert tools and accessories for the TE 30, TE 30‑AVR, TE 30‑C and TE 30‑M
Designation
Chuck
Chuck
Hammer drill bits
TE‑C percussion core bits
TE‑T percussion core bits
TE‑C forming and installation drill bits
Anchor-setting tools
Quick-release chuck for wood and metal drill bits
Wood drill bits
Metal drill bits
Insert tools for the TE 30‑C‑AVR and TE 30‑M‑AVR
Designation
Pointed chisels
Flat chisel
Shaped chisels
Insert tools and accessories for the TE 30‑M‑AVR
Designation
TE‑C lightweight percussion core bits
Multipurpose hole saws
Metal drill bits / stepped drill bits
4
14 AWG
75 ft
Description
TE‑C (SDS Plus)
TE‑T (SDS Top)
∅ 5...25 mm (¼ - 1")
∅ 66...90 mm (2¾ - 3½")
∅ 50...90 mm (2 - 3½")
∅ 10...35 mm (³/₈ - 1³/₈")
TE‑C or TE‑T connection end
For smooth or hex. shank
∅ 5...25 mm (¼ - 1")
∅ Max. 13 mm (up to ½")
Description
TE‑C or TE‑T connection end
TE‑C or TE‑T connection end
TE‑C or TE‑T connection end
Description
∅ 25...68 mm (1 - 2½")
∅ 35...105 mm (2½ - 4¹/₈"), Hex. connection end
∅ 3...8 mm (¹/₈ - ³/₈"), (2nd gear) hex. connection end
12 AWG
125 ft