an "s" for switch. This function is important for controlling DMX switches, for example the SW-5DMX. As a
check for the user, an "s" for a switching function is placed in front of the DMX value above the fader.
-2. Description of the master function. As already described above under 2.1.2, the numbers of the buttons
can get a red marking to activate the master function for this channel.
-3. Synchronous function: in certain cases a synchronous control of two or several channels is desired, e.g.
the gobos of several scanners for parallel operation. The buttons of the desired channels get a blue marking.
Keep the Alt button pressed, go with the mouse pointer to the desired button and click on it with the left
mouse button. The color of the channel number on the flash button becomes blue. Repeat this procedure for
all channels to be controlled synchronously. All "blue" channels now get the value of the last activated (blue)
fader. If the flash button of such a channel is pressed, all "blue" faders get the maximum value and then go
back to the common original value. To deactivate the synchronous function of a channel, repeat the
procedure just described.
Note: The master function and the synchronous function operate on several levels at the same time, i.e. the
markings of one fader are also valid on an invisible level.
2.1.4 Changing the levels
On the main desk always 12 channel faders and one master fader are available. Only the last level has 6
channels (505-510). To have access to further channels or faders, the levels can be changed with the
command fields 1-12, 13-24, ... up to 505-510. The numbers designate the channels respectively available on
the selected level. When switching, the fader positions of the other levels are maintained. The respectively
active level is marked by the red lettering of the corresponding level button.
2.1.5 C-Reset
The DMX output is stopped with the button "C-RESET" and the coverter box is reset. The USB port is set to
a defined output condition. To reactivate the DMX output, the button "DMX Start" has to be activated.
2.1.6 BO Black Out
When activating this button, all channels which have the master function are set to zero. All channels with
red marked flash buttons are concerned. As long as Black Out is activated, the button flashes as a check.
Press the BO button again to deactivate the Black Out function.
2.1.7 DMX Start/DMX Freeze
The DMX output is switched on and off with this button. The USB port remains at "DMX Freeze" in the
current output status. The converter box is going on to transmit its DMX commands last reached. The upper
LED (Send) above the level buttons serves as an indicator for the transmitting status. In case of DMX Start it
flashes, in case of DMX Freeze it remains white.
2.1.8 Automatic On
With this software it is possible to create up to 500 scenes per sequence. Separately from the sequence, the
scenes can be saved as a block in a file and be called again. Under the menu item "Program/Create Sequence"
the scenes can optionally be created in any desired order and frequency for a sequence. In the DMX -510USB
there are four new sequence tables. With these sequence tables it is possible to create four independent
sequences with the scenes. Then the created sequences can run automatically (all with independent timers).
With 'Automatic On' sequences A-D will be started.

2.1.9 Automatic Off