Initial Operation - Metabo KHE 2660 Quick Instrucciones De Manejo

Ocultar thumbs Ver también para KHE 2660 Quick:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

en
ENGLISH
4 Keyless chuck *
5 Sleeve keyless chuck *
6 Spindle
7 Additional handle
8 Depth stop
9 Lock
10 Switch button (for changing the operating
mode)
11 Electronic signal indicator *
12 Speed preselection wheel *
13 Rotation selector switch
14 Lock button
15 Trigger switch
* depending on equipment/not in scope of delivery

5. Initial Operation

Before plugging in, check that the rated mains
voltage and mains frequency, as stated on the
type plate match your power supply.
Always install an RCD with a maximum trip
current of 30 mA upstream.
5.1
Assembly of the additional handle
For safety reasons, always use the additional
handle supplied.
Open the clamping ring by turning the side handle
(7) counter-clockwise. Push the additional handle
onto the collar of the machine. Insert the depth stop
(8). Securely tighten the additional handle at the
angle required for the application.
6. Use
6.1
Depth Stop Setting
Loosen the additional handle (7). Set the depth stop
(8) to the desired drilling depth and retighten
additional handle (7).
6.2
Switching On and Off
Press the trigger switch (15) to switch on the
machine.
The speed can be changed using the trigger switch.
UHEV 2860-2 Quick:
The electronic soft start means that the machine
accelerates continuously up to the pre-selected
speed.
For continuous operation, the trigger button can be
locked using the lock button (14) . Press the trigger
switch again to stop the machine.
In continuous operation, the machine
continues running if it is forced out of your
hands. Therefore, always hold the machine with
both hands using the handles provided, stand
securely and concentrate.
6.3
Select speed (only for UHE...)
Select the optimal speed at the thumbwheel (12)
depending on the application.
6
6.4
Operating mode selection
Press the lock (9) and turn the thumbwheel (10).
Hammer drilling
(Set only when using the hammer chuck (1) )
Chiselling
(Set only when using the hammer chuck (1) )
Setting chisel position
Turn the chisel in the desired position. Then
select "Chiselling" to secure the chisel and
prevent it from twisting.
Only for KHE...:
Drilling
(high torque)
Only for UHE ...:
Drilling 1st gear
(high torque)
Only for UHE ...:
Drilling 2nd gear (high speed)
When a chisel is fitted, only operate the
machine in the chiselling operating mode
Avoid levering with the machine when a chisel
is fitted.
6.5
Selection of direction of rotation
Only activate the rotation selector switch (13)
when the motor has completely stopped.
Select direction of rotation:
R = clockwise rotation (for drilling, hammer
drilling, chiselling, drive in screws)
L = anti-clockwise rotation (for the removal of
screws)
6.6
Drill chuck change
Ensure a clean spindle (6) when changing the
chuck. Apply a light coating of grease to the
spindle. (Special grease: Order No.: 6.31800)
Only attach the Metabo chuck provided.
Removing the chuck:
See page 2, fig. C.
- Turn the chuck lock (3) in the direction of the arrow
until the stop (a) and remove chuck (b).
Replacing the chuck:
See page 2, fig. D.
- Put the chuck onto the spindle (6) (a).
- Turn the chuck lock (3) in the direction of the arrow
(b) until the chuck can be pushed completely onto
the spindle and release the chuck lock.
- Check to see that the chuck is properly seated.
Note: To prevent the spindle from rotating when the
chuck is being changed, put the switch button (10)
to chiselling
.
6.7
Tool change with SDS chuck
Before fitting, clean tool shank and apply
special grease (accessories order no.
6.31800)! Use only SDS-Plus tools.
.
Tabla de contenido
loading

Este manual también es adecuado para:

Khe 2860 quickUhe 2660-2 quickUhev 2860-2 quick

Tabla de contenido