en
ENGLISH
Reduce dust exposure with the following measures:
- do not direct the escaping particles and the
exhaust air stream towards yourself or nearby
persons or towards dust deposits,
- use an extraction unit and/or air purifiers,
- ensure good ventilation of the workplace and keep
it clean using a vacuum cleaner. Sweeping or
blowing stirs up dust.
- Vacuum or wash protective clothing. Do not blow,
beat or brush protective gear.
5. Overview
See page 1.
1 Geared chuck
2 Side handle
3 Slide switch
4 Handle
5 Speed preselection wheel
6. Initial Operation
Before plugging in, check to see that the rated
mains voltage and mains frequency, as stated
on the rating label, match with your power supply.
Always install an RCD with a max. trip current
of 30 mA upstream.
6.1
Side handle installation
For safety reasons, always use the side
handle supplied.
7. Use
7.1
Switching On and Off
To switch On (continuous activation): Push the
slide switch (3) forwards until it engages.
To switch Off: Push the slide switch (3) to the rear
end.
In continuous operation, the machine
continues running if it is forced out of your
hands. Therefore, always hold the machine
with both hands using the handles provided,
stand in a safe position and concentrate.
7.2
Preselecting the speed
Use the setting wheel (5) to pre-select the max.
speed.
7.3
Tool change with a geared chuck
3x
10
Chucking the tool:
Insert the tool and use the chuck key to uniformly
clamp tight all 3 bores.
Removing the tool:
Open the geared chuck with the chuck key and
remove the tool.
7.4
Remove chuck
Open chuck completely. Put Allen key - through the
chuck - into the machine's spindle. Hold Allen key
firmly (e.g. in a vice).
Loosen chuck by lightly tapping on the fitted Allen
key with a rubber mallet and remove it.
f
8. Accessories
Use only genuine Metabo accessories.
Use only accessories which fulfil the requirements
and specifications listed in these operating instruc-
tions.
For a complete range of accessories, see
www.metabo.com or the main catalogue.
9. Troubleshooting
- Overload protection: There is a MAJOR
reduction in load speed. The motor temperature
is too high! Allow the machine to run at idle speed
until it has cooled down.
- Overload protection: There is a SLIGHT
reduction in load speed. The machine is
overloaded. Reduce the load before continuing to
work.
- Restart protection: The machine does not
start. The restart protection is active. If the mains
plug is inserted with the machine switched on, or if
the power supply is restored following an
interruption, the machine does not start up. Switch
the machine off and on again.
10. Repairs
Repairs to electrical tools must be carried out
by qualified electricians ONLY!
A defective mains cable must only be replaced with
a special, original mains cable from metabo, which
is available only from the Metabo service.
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. For
addresses see www.metabo.com.
You can download a list of spare parts from
www.metabo.com.
11. Environmental Protection
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Guideline 2012/
19/EU on used electronic and electric equipment
and its implementation in national legal systems,