6 Commissioning
6.4 Feeding in the wire
NOTICE
• Each time you change the wire, make sure that the start of the wire is free of burrs.
1
2
8
1
MasterLiner
2
Inlet tube
Fig. 5
Feeding in the wire
CAUTION
Risk of injury
Physical injury caused by the start of the wire.
• Keep the process-side drive away from the body.
1 Lift off the cover (3).
2 Press on the rocker (7) then rotate the eccentric bolt (8) and remove it upwards.
3 Fold away the rocker (7) to the side.
4 Insert the wire (4) from the wire drum or spool through the MasterLiner (1) to the inlet tube (2).
5 Swivel the rocker (7) into position, insert the eccentric bolt (8) and turn it over.
6 Press the inching trigger (6) until wire comes out of the MF1 (process-side wire drive).
NOTICE
• For further steps, please see the MF1 operating instructions.
EN - 12
7
3
Cover
4
Wire
6
5
MasterLiner
6
Inching trigger (green)
MF1-Rear
3
4
5
7
Rocker
8
Eccentric bolt
BAL.0410.0 • 2018-08-15