6 Putting into operation
6.5 Feed in wire
1
Cover
2
Pressure lever
Fig. 8
Feed in wire
1 Open cover (1) at M-Drive (2) .
2 Fold pressure lever (2) forward and open pressure rockers (4) .
3 Untie beginning of wire on the wire basket spool.
4 Insert wire through the inlet tube (5) over the drive rolls (6) into the distance adaptor (4).
5 Close pressure rockers (4) fold pressure lever (2) back.
6 Press the Inching trigger, feed the wire with the cover (1) open through the cable assembly into the
process-side drive.
Risk of injury
Bodily harm caused by the beginning of the wire.
• Keep process-side drive away from the body.
7 Close and lock cover (1) .
EN - 10
1
2
8
7
6
3
M-Drive
4
2 pressure rockers
CAUTION
3
4
5
5
Distance adaptor
6
drive rolls
MFS-V2
7
Inlet tube
8
Safety switch