Preparatory work
–
Pull out the control knob (3 – gas).
–
Remove the cover (11).
All control elements (4, 5) are fixed into the cover via
lugs. The control elements can be dismantled again by
pressing these lugs and pushing them at the same time.
–
If available, disconnect the cable (14) of the integrated con-
trol panel (5) for the fan. Dismantle the control panel and
dispose of correctly. If necessary repeat this process for the
second control panel.
–
Dismantle the knob socket (4) and dispose of correctly.
5
12
14
10
3
11
4
13
Important note
The knob socket (4) always needs to be mounted on the con-
trol rod side (13).
Every control element / blank cover has a small and a large
lug. Therefore do not exert force onto the cover. Always en-
sure the lugs are in the correct position during assembly.
The figures on the right show installation.
Mount the sensor PCB
An electro-static charge can destroy the electronics.
Ensure potential equalisation before touching the
electronics.
–
Place the cover (11) with the operating side on an even,
clean surface.
–
Position the sensor PCB (2) and click into place.
11
2
11