When adjusting the sensor with Dynasoft Adjustment
software, the product must first be put in sleep mode
and the relays disabled. To do this:
EN
• Switch off the product by performing a long press on
the keyboard button for standby mode (item F fig 1).
The network indicator should flash red.
• If the relays have been connected, press the test
button for 6 seconds (item E, fig 1). The relays are
§5.9.4
now disabled for 15 minutes.
See the Dynasoft Adjustment manual for the calibration.
5.9.4. Single-sensor main display
B
C
N
J
K
A
Measurement
B
Tractel logo
C
Unit of measurement
D
Measurement filter (see 5.9.10.2)
E
Threshold trip filter (see 5.9.10.2)
F
Built-in buzzer (see 5.9.14)
G
Product battery indicator
H
Status of the connection to the sensor
I
Time
J
Sensor logo (differentiated according to the Dynafor
Pro, Expert and Transmitter WL & RS models)
K
Sensor batteries indicator
L
Identification of sensor (designation + last nine digits
in serial number)
M
Sensor capacity in t
N
Values of set thresholds (see 5.9.14)
In the case of multiple sensors, the change of page is
done by pressing the right or left button. (See figure 1.)
The markers H, J, K, L, M and N are updated with the
new sensor information.
10
§5.9.5
E
D
F
G
L
5.9.5. Tare function
The tare function is used to indicate the net force of
the load.
The tare function allows the value displayed on the
product to be reset to zero. This function is activated by
pressing the tare button (item G, fig. 1) for two seconds.
It is then possible to apply a force and display its net
value.
Pressing the Tare button switches from the net value to
the gross value.
H
I
A
M
A
TARE indicator
B
Net measurement if TARE reference present
Gross measurement if TARE reference missing
C
Actual load display bar in relation to its SWL
The display bar C changes according to the actual
gross load. Indicator A indicates that tare mode has
been activated.
When the SWL of the sensor is exceeded (100%), the
display bar turns red.
If the SWL is exceeded by more than 10%, an overload
message appears. (See 5.9.15.)
NB: When the tare function is activated,
TM
decreasing the force may cause the display to turn
negative as the case may be.
NB: In the case of multiple sensors, the page
is changed by pressing the left or right button. It is
possible to apply one tare per sensor.
NB: The peak load function is not available
when the tare function is activated.
A
B
C