REMOVING THE HOB:
To remove the hob, rst, disconnect it from the electric supply. It is strongly recommended to free the underneath part from the oven, drawer, separator, or other.
It allows the technician to access the lower part of the hob to unfasten the four clips with a screwdriver, lift the hob and remove it, avoiding any worktop damage.
ELECTRICAL CONNECTION
Electrical connection must be made before connecting the appliance to the electricity supply.
The power cord is not included in the package - remember to prepare your own power cord.
Installation must be carried out by quali ed personnel who know the current safety and installation regulations. Speci cally, installation must be carried out in
compliance with the regulations of the local electricity supply company.
Make sure the voltage speci ed on the data plate located on the bottom of the appliance is the same as that of the home.
Regulations require that the appliance be earthed: use conductors (including the earth conductor) of the appropriate size only.
CONNECTION TO THE TERMINAL BLOCK
For the electrical connection, use an H05RR-F or H05V2V2-F cable as speci ed in the table below.
SUPPLY VOLTAGE
3 x 4 mm
220-240V ~ +
3 x 4 mm
230-240V ~ +
4 x 1,5 mm
220-240V 3~ +
5 x 1,5 mm
380-415V 3N~ +
4 x 1,5 mm
380-425V 2N~ +
The appliance must be connected to the electricity supply by means of an all-pole disconnect switch with minimum contact gap of 3 mm.
ATTENTION: the power supply cable must be long enough to allow the cooktop to be removed from the worktop and must be positioned so as to avoid
damage or overheating caused by contact with the base.
NOTE: the yellow/green earth wire must be connected to the terminal with the symbol
Remove approx. 70 mm of the cable sheath from the power supply cable (B).
•
•
Strip approx. 10 mm of sheath from the wires. Then insert the power supply cable into the cable clamp and connect the wires to the terminal block as
indicated in the connection diagram placed close to the terminal block itself.
•
Secure the power supply cable (B) by means of the cable clamp.
Close the terminal board with the cover (A) securing it with the screw provided.
•
•
After the electrical connection, t the hob from the top and hook it to the support springs, according to the illustration.
CONDUCTORS
AMOUNT x SIZE
2
2
(Australia only)
2
2
2
B
and must be longer than the other wires.
A