Service
Service
Maintenance
Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.
Service recommendations
Overhaul and preventive maintenance is recommended at regular intervals. See the Preventive mainte-
nance section for detailed information regarding overhaul of your tool and specific parts. If the machine is
not working properly, it should immediately be taken away for inspection. At the overhauls, all parts should
be cleaned accurately and defective or worn parts should be replaced.
Service instructions
Overhaul and preventive maintenance is recommended at regular intervals once per year or after maxi-
mum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed if
used at high torque, high cycle rate or long tightening times. If the machine is not working properly, it
should immediately be taken away for inspection.
At the overhauls, all parts should be cleaned accurately and defective or worn parts (i.e. O-rings) should
be replaced.
Cleaning/Inspection
Clean all parts thoroughly in white spirit or similar cleaning agent. After the cleaning, inspect all parts.
Damaged and worn parts should be replaced.
Lubrication
Overhaul
Service must only be carried out by qualified personnel who have access to the Service instruction and/or
have been trained for service on Tensor ST Tools.
The electric motor is a sealed unit and may under no circumstances be opened by anyone else than Atlas
Copco Industrial Technique AB!
If it is judged that the electric motor is defect or in need of service, the complete motor unit should be re-
turned to Atlas Copco Tools for exchange.
Motors which have been opened by anyone else than Atlas Copco Tools will not be serviced.
8
EN
© Atlas Copco Industrial Technique AB - 9836 8491 00
ETVST61-28-10