16.1 RIGHT WHEEL MOTOR CONTROLLER ERROR CODES
Error Co-
Errors Contents
des
TR 2
Drive motor stalled
TR 5
Motor encoder error
TR 6
Controller phase loss
TR 7
MOSFET error
TR 8
Controller undervoltage
TR 9
Controller overvoltage
TR 12
Motor overtemperature
TR 13
Controller overtemperature
TR 14
Overcurrent-Level 1
TR 15
Overcurrent-Level 2
TR 16
Speed controller error
TR 19
Operating sequence error
TR 21
ETO relay error
TR 22
Magnetic valve error
TR 23
Battery compartment
(PMU)communication error
TR 24
Battery compartment (PMU)
error
TR 25
CAN timeout error - left drive
TR 26
CAN timeout error - right
drive
TR 27
CAN timeout error - left blade Communication failure with the left blade controller. Restart the power
English
Suggetions
Check if the drive wheels are stuck and restart the power supply.
Check that the connector of motor is properly connected with the drive
controller, and then restart the power supply.
Check that motor cables of the drive controller are connected properly,
and then restart the power supply.
If you encounter this issue, contact your distributor for a solution.
The voltage is too low. Charge the battery pack before use.
The voltage is too high. Restart the power supply.
The motor temperature is too high. Wait for the motor to cool down, and
then restart the power supply.
The controller temperature is too high. Wait for the controller to cool
down, and then restart the power supply
The load is too high. Restart the power supply.
The load is too high. Restart the power supply.
Check that the speed controller of handle is connected properly, and
then restart the power supply.
Place the left and right levers in the park position and try again.
Restart the power supply.
Check that the solenoid valve of drive motor is connected properly, and
then restart the power supply.
Communication failure with battery compartment. Restart the power
supply.
Minor/major error in battery compartment. Perform a check and restart
the power supply.
Communication failure with the left drive controller. Restart the power
supply.
Communication failure with the right drive controller. Restart the power
supply.
supply.