2) Remove the carbon brush support assembly from its housing.
3) Unplug the lug, press the carbon brush to mount it in its housing and remove the braid from the
support
4)
Disengage the spring to release the carbon brush.
5) Perform the same operation for the opposite carbon brush. Once both carbon brushs are
changed, refit the black cover, being careful not to pinch the wires, then install the cable
cover and carefully screw the back of the motor.