INNOVATIVE ORBITAL SOLUTIONS
10. Maintenance and repair of the machine
-
Maintenance operations must be performed by qualified personnel using genuine Axxair spare
parts.
Prior to any repair, disconnect the machine from the power source.
-
-
Store and transport the machine, as well as any machine accessories, using the original shipping
crate.
-
For best results, keep the machine clean.
Clean the machine using the brush supplied in the case and lubricate after each use.
-
Do not allow the machine to remain unprotected in a corrosive, salt air or humid environment.
-
It is very important to keep foreign objects away from the machine's rotation system.
To clean the machine, use the brush provided.
Never clean the machine using compressed air.
WARNING
Motor references: GA10N-COA10 (220V) – GA10N-COA11 (110V)
1) Unscrew the TORX screw on the back of the motor (key TX20), then remove the black
cover.
Join
experience
Danger of electric/pneumatic motor disassembly.
Fatal electric shock, various physical injuries or material damage
Recommandations: Verify that the machine is unplugged from any power source
(electric, other...)
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
Carbon brush references :
METABO motor 110 and 220 V :
316067170 (220V)
316066670 (110V)
330B Route de Portes Les Valence - 26800 Etoile sur Rhône
English