Maytag Commercial MAT20MNTGW Manual De Instrucciones página 11

Ocultar thumbs Ver también para MAT20MNTGW:
Idiomas disponibles

Idiomas disponibles

Power Cord Replacement
Instructions
The steps in this section shall only be performed by a Maytag
service person, qualified electrician, or similarly qualified person.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. The appliance shall be disconnected from the power supply
before servicing. Read all instructions before any disassembly.
2. Remove retaining screw securing power cord assembly to the
product and save for re-installation.
Retaining
Screw
3. Rotate the power cord strain relief bracket within the machine
console and remove at an angle from the opening in the back
panel to expose access to the inner connector. The inner
connector is still connected. Do not put strain on the conductors
while removing the bracket to allow access to the connector.
Twist
Remove at
Angle
Outside Product
Inside Product
4. Disengage the supply connection within the product by
depressing the connector clip to release the power cord from
the appliance.
Press
5. Remove the U-Clip from the strain relief bracket by sliding
downward and save for re-installation.
U-Clip
6. Remove the cord from the strain relief bracket and follow the
cord installation steps 7-12. Save the strain relief bracket for
re-installation.
Power Cord
7. Select the regionally required cord/plug and slot it through the
strain relief bracket.
Strain Relief
Bracket
11
loading

Este manual también es adecuado para:

Mat20cstgwMat20mntkwMat20mnagw