Command and safety device status display mode

COMMAND STATUS
AP
PED
PP
CH
ORO
POWER
COMMAND STATUS:
The command status indicators on the display are normally OFF.
They ILLUMINATE when a command is received (e.g.: when a step mode command is received, the segment PP
illuminates).
SEGMENT
COMMAND
open
step-by-step mode
close
partial opening
clock
SAFETY DEVICE STATUS:
The safety device status indicators ON the display .
If an indicator is OFF, the relative device is in alarm state or is not connected.
SEGMENT
SAFETY
FT1 photocells
FT2 photocells
COS1 sensing edge
COS2 sensing edge
gate open limit switch
gate closed limit switch
release lever open
8.3

TEST mode

To activate the mode, press the TEST button with the automatic door system at rest. If the gate is moving, pressing
TEST stops the gate. Pressing the button again enables TEST mode.
device is activated.
SAFETY DEVICE STATUS
FT1
FT2
COS1
COS2
SB
STOP
The command signal status is shown on the left hand side of the display for
5 seconds, ONLY when the respective command signal is active (AP, CH, PP,
PE, OR). For example, if the gate open command is activated, the letters AP
appear on the display.