PERFORMANCE DATA SHEET
Water Filtration System
Model
P6WB2L/P6RFWB2
Capacity
200 Gallons
(757 Liters)
Model
P6WB2NL/P6RFWB2
Capacity
200 Gallons
(757 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, and Particulate
Class I*; and against
NSF/ANSl
Standard
53 for the reduction
of Live
Cysts, Asbestos,
Lead, Lindane, Toxaphene,
Atrazine,
and 2,4 - D.
This system
has been tested
according
to NSF/ANSl
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSl
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Live Cysts t
Asbestos
Lead: @ pH 6.5
Lead: @ pH 8.5
Lindane
Toxaphene
Atrazine
2,4 - D
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
99.95%
99%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
0.07 mg/L
Average
Influent
2.0 mg/L
7,300,000 #/mL
Average
Influent
160,000/L
87 MFL
0.160 mg/L
0.140 mg/L
0.0019 mg/L
0.014 mg/L
0.0094 mg/L
0.220 mg/L
Influent Challenge
Concentration
2.0 mg/L + 10%
At least 10,000 particles/mL
Influent
Challenge
Concentration
50,000/L min.
107to 108fibers/L tt
0.15 mg/L _+10%
0.15 mg/L_+ 10%
0.002 mg/L _+10%
0.015 mg/L _+10%
0.009 mg/L_+ 10%
0.210 mg/L_+ 10%
Maximum
Effluent
0.20 mg/L
75,000 #/mL**
Maximum
Effluent
54/U
0.17 MFL
0.001 mg/L
0.005 mg/L
0.00002 mg/L
0.001 mg/L
0.0005 mg/L
0.028 mg/L
Minimum %
Reduction
97
99
Minimum %
Reduction
99.97
99
99.4
98.6
98.9
93
94.5
87.5
Test Parameters:
pH = 7.5 + 0.5 unless otherwise
noted.
Flow = 0.43 gpm (1.6 Lpm). Pressure
= 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 200 gallons
(757 liters).
•
It is important
that operational,
maintenance,
and filter
•
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Property
damage
can occur if all
instructions
are not followed.
•
Use replacement
filter P6RFWB2.
2014 suggested
retail price of
$39.99
U.S.A./S49.99
Canada.
Prices are subject
to change
without
notice.
Style
1 - When Order Filter is illuminated
yellow, order a new
filter. When Replace Filter is illuminated
red, it is recommended
that you replace the filter.
Style 2 - Press OPTIONS
or SETTINGS
and select Filter Status
to check the status of your water filter. When the filter status
shows 10% remaining,
order a new filter. When the filter status
shows 0% remaining,
it is recommended
that you replace the
filter.
Style 3 - Press FILTER STATUS to check the status of your water
filter. When the filter status shows
10% remaining,
order a new
filter. When the filter status shows 0% remaining,
it is
recommended
that you replace the filter.
•
After changing
the water filter, flush the water system.
See
"Water and Ice Dispensers"
or "Water
Dispenser"
in the User
Instructions
or User Guide.
•
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
•
The product
is for cold water use only.
•
The water system
must be installed
in compliance
with state and
local laws and regulations.
Average
%
Reduction
97.2
99.4
Average
%
Reduction
99.99
99
99.4
98.6
99
93
94.7
96.1
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters that may contain
filterable
cysts.
•
Refer to the "Warranty"
section
(in the User Instructions
or User
Guide) for the Manufacturer's
name, address
and telephone
number.
•
Refer to the "Warranty"
section
(in the User Instructions
or User
Guide) for the Manufacturer's
limited warranty.
Application
Guidelines/Water
Supply Parameters
City or Well
30 - 120 psi (207 - 827 kPa)
33 ° _ IO0°F (0.6 ° - 37.8°C)
0.43 gpm (1.6 Lpm) @ 60 psi
Water
Supply
Water
Pressure
Water
Temperature
Service
Flow Rate
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tBased on the use of Cryptosporidium
parvum oocysts
ttFibers greater than 10 um in length
® NSF is a registered trademark
of NSF International.
35