Kenmore 596.7238 Manual De Uso página 13

Ocultar thumbs Ver también para 596.7238:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

.
6.
Place the free end of the tubing into a container or sink, and
turn on main water supply to flush out tubing until water is
clear. Turn off shutoff valve on the water pipe.
NOTE: Always drain the water line before making the final
connection to the inlet of the water valve, to avoid possible
water valve malfunction.
Bend the copper tubing to meet the water line inlet, which is
located on the back of the refrigerator
cabinet as shown.
Leave a coil of copper tubing to allow the refrigerator
to
be pulled out of the cabinet or away from the wall for
service.
Connect to Refrigerator
Follow the connection instructions specific to your model.
Style I
1. Remove plastic cap from water valve inlet port. Attach the
copper tube to the valve inlet using a compression nut and
sleeve as shown. Tighten the compression nut. Do not
overtighten.
Confirm copper tubing is secure by pulling on
copper tubing.
2. Create a service loop with the copper tubing. Avoid kinks
when coiling the copper tubing. Secure copper tubing to
refrigerator
cabinet with a "P" clamp.
c
D
.
A. Copper tubing
B. "P" clamp
C. Compression
nut
D. Compression
sleeve
Turn on water supply to refrigerator
and check for leaks.
Correct any leaks.
Style 2
I.
Unplug refrigerator
or disconnect power.
2. Remove and discard the short, black plastic part from the
end of the water line inlet.
.
Thread the nut onto the end of the tubing. Tighten the nut by
hand. Then tighten it with a wrench two more turns. Do not
overtighten.
NOTE: To avoid rattling,
be sure the copper tubing does not
touch the cabinet's side wall or other parts inside the
cabinet.
4.
5.
6.
7.
A
B
C
D
A. Household
water
line
C. Ferrule
{purchased]
B. Nut
(purchased)
D. Refrigerator
water
tubing
Install the water supply tube clamp around the water supply
line to reduce strain on the coupling.
Turn shutoff valve ON.
Check for leaks. Tighten any connections (including
connections at the valve) or nuts that leak.
On some models, the ice maker is equipped
with a built-in
water strainer. If your water conditions
require a second
water strainer, install it in the 1/4" (6.35 mm) water line at
either tube connection. Obtain a water strainer from your
appliance
dealer.
Complete
the Installation
Electrical
Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1. Plug into a grounded 3 prong outlet.
2. Flush the water system. See "Water
and Ice Dispensers."
NOTE: Allow 24 hours to produce the first batch of ice. Discard
the first three batches of ice produced. Allow 3 days to
completely
fill the ice storage bin.
13

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

W10675342a

Tabla de contenido