Discharge Pipe and Pressure Tank Connections
Pressure Gauge
and Priming
Plug
Pressure
Switch
Figure 6: Pre-charged Tank
Connections
To Household
Water System
Air Volume
Control
Air Volume
Control Tube
Priming Tee
and Plug
Relief Valve
Pressure
Switch
Figure 7: Standard Tank Connections
Pre-Charge Tank Connection (Figure 6)
To Household
If your system uses a pre-charged tank, it should be connected to the pump
Water System
as shown in Figure 6. The relief valve must be capable of passing the entire
pump capacity at 100 PSI pressure.
Relief
Check the pre-charge of air in the tank with an ordinary tire gauge. the pre-
Valve
charge is measured when there is no water pressure in the tank. Disconnect
power to the pump and drain the tank before checking the pre-charge.
Your pump has a 30/50 PSI switch, so the tank pre-charge pressure should
From
be 28 PSI (that is, it should be 2 PSI lower than the cut-in pressure of the
Well
pressure switch.
No AVC is required for a pre-charged tank; the 1/8" NPT AVC port on the
pump body should be plugged.
Standard Tank Connection (Figure 7)
If your system uses a standard tank, connect it to the pump as shown in
Figure 7. The relief valve used with a standard tank must be capable of
passing the entire pump capacity at 75 PSI pressure.
Connect the Air Volume Control (AVC) tube to the 1/8" NPT AVC port
on the pump body. Run the tubing from the pump's AVC port to the AVC
mounted on the tank. See the instructions provided with tank and AVC
for details.
268 0395
Use only PTFE pipe thread sealant tape or PTFE-based joint compounds
for making all threaded connections to the pump itself. Do not use pipe
joint compounds on plastic pumps: they can react with the plastic in
pump components. Make sure that all pipe joints in the suction pipe are
air tight as well as water tight. If the suction pipe can suck air, the pump
will not be able to pull water from the well.
From
Well
276 0395
Sealing Pipe Joints