Ford LJ98-10C823-AC Manual De Instrucciones página 6

Ocultar thumbs Ver también para LJ98-10C823-AC:
Idiomas disponibles

Idiomas disponibles

WARNING
- When not in use, store the charging cable in the
designated holder and lock the charging coupling
in the remote dock. Loosely wind the charging ca-
ble around the remote dock making sure the ca-
ble does not touch the floor.
- You must make sure that the charging cable
and coupling cannot be driven over, trapped, and
are protected from all other hazards.
WARNING
- Immediately notify Customer Service if the
charge station, charging cable or the charging
coupling are damaged. Do not continue to use
the charge station.
- Prevent the charging cable and coupling from
coming into contact with external heat sources,
water, dirt, and chemicals.
- Switch off power at the circuit breaker before
installing or cleaning.
- Do not attach extension cables or adapters to
the charging cable.
- Never clean the charge station with a high-pres-
sure cleaner or similar.
- Switch off the power supply before cleaning the
charging sockets.
- The charging cable must not be subjected to
any strain during use.
- You must make sure that no one has access to
the charge station without reading this user
manual first.
- Make sure that the charge station temperature
is within its storage temperature limits when
moving, transporting, or storing it.
- You are strictly prohibited from pulling the
charge station by its cable.
- The Ford Connected Charge Station must be
connected directly to your home's mains connec-
tion; no plugs and sockets must be used.
- You may only operate the charge station after
professional installation.
6
WARNING
When transporting the Ford Connected Charge
Station , handle with care. Do not subject it to
strong force or impact, also do not pull, twist,
tangle, drag, or step on the Ford Connected
Charge Station, to prevent damaging it or any of
its components.
NOTICE
In addition to the safety instructions in this docu-
ment, also observe further safety instructions in
any other enclosed documents.
3
Unit description
This document describes the Ford Connected Charge Sta-
tion. You can find the exact device details on the type label
of the Ford Connected Charge Station.
Electrical
Ford Connected Charge Station
characteristics
Nominal current (A)
48A
(configurable con-
nected load values)
Line voltage (VAC)
240 V (Line-to-Line voltage) / 208 V
(nominal)
Grid frequency (Hz)
60 Hz
(nominal)
Overvoltage cate-
III
gory
Protection class
I
Integrated power
Accuracy +/- 5%
meter
Connections
Cable feed
Mounted on-wall, or in-wall
Connection cross-
2x 6 AWG (L1/L2) 1x 8 AWG (GND) for
section
the charging cable only
(wire dimension)
(observe local codes/regulations)
Charging cable (in-
Charging cable with Type 1 coupler ac-
cluding coupler)
cording to SAE J1772
Cable length 20 ft / approximately 6
m
LJ98-10C823-AC / LJ98-10C823-AD
Electrical
Ford Connected Charge Station
characteristics
Output voltage
240 V and 208 V
(VAC)
Maximum charging
11.5 kW
capacity (kW)
Wire dimension
Power supply cable L1 / L2 / PE cross-
section up to 2 AWG (35 mm²)
Communication &
features
Vehicle–charger
SAE J1772
Communication Pro-
tocol (CP)
Authentication
Bluetooth (BLE 4.2) – Setup App
Display
9 RGB-LEDs
Network interfaces Wi-Fi 802.11n – 150 Mbit/s
Authentication and
Bluetooth (BLE 4.2) - Setup-App
mobile communica-
tions
OCPP
Version 1.6
Mechanical data
Dimensions (W × H ×
10.2 x 17.7 x 5.5 Inches
D)
258 x 450 x 141 mm
Weight (including
17.53 lbs
wall mount bracket
7.95 kg
& charging cable)
Installation height
Minimally 35 inches above floor level
(to the bottom of the device)
Minimally 900 mm above floor level
(to the bottom of the device)
NEMA protection
NEMA 3S
class
Protection against
ANSI/UL2594:2016
mechanical impact
Ambient conditions
Operating tempera-
-40°F to +122°F
ture range
-40°C to +50°C
Storage temperature
-40°F to +185°F
range (°C)
-40°C to +85°C
Ford Connected Charge Station Operation Manual
loading

Este manual también es adecuado para:

Lj98-10c823-ad