7.1

MENU panel

For each of the main measurement functions, described in sec. 6.1-6.12, there are sub-functions
available. They may be selected by pressing F1 button in MENU.
In addition to the functions described in section 6, the meter determines:
peak values of measured signals
Crest Factor
constant and periodic component of voltage and current
frequency and half-period
relative values of the measured values
Select the desired mode using arrows and F1 F2 F3 F4 buttons.

7.1.1 Displaying AC and DC components

The meter measures the AC and DC component of the measured signal (voltage or current).
Readings of these values may be displayed separately or together, as shown below.
From MENU the following modes are available:
AC+DC – reading is the sum of a periodic and constant component,
DC, AC – the main reading is constant component.
Measurement of peak values, frequency, duty cycle, relative values and frequency in this mode
is not available.