Start programming mode
Programme opening
Programme closing
Finish the programming mode
1 Place DIP1 and DIP3 in "OFF".
DL3 will remain off.
The pedestrian open/close is now memorised.
PROGRAMMING AND STARTUP
1 Close the gate by pressing PUL1.
2 Place DIP1 and DIP3 in "ON" (pedestrian opening
programming); DIP2, DIP4, DIP6, DIP7, DIP9 and
DIP10 in "OFF".
DL3 lights up, statically.
3 Installations with electrolock: place DIP5 in "ON"
(back pulse).
4 In operators with mechanical absorbers (such as
hydraulic motors), place DIP8 in "OFF" (electric soft
stop disabled).
1 Start opening: press ST2; the gate begins to open.
2 Start slow down on opening (with DIP8=ON
only): press ST2 at the point chosen for the start of
deceleration (DA).
3 Finish opening: Press ST2 in the gate open
position.
1 Start closing: press ST2; the gate begins to close.
2 Start slow down in closing (with DIP8=ON only):
press ST2 at the point chosen for the start of
deceleration (DC).
3 Finish closing: Press ST2 in the gate closed position.
The positions in which the leaf begins to slow
down, both on opening and in closing, are also
memorised (with DIP8=ON only).
Control board VIVO-M201(M)