DESCRIPTION OF THE PRODUCT
2
CONTROL BOARD FEATURES
The VIVO-M201(M) control board is built to form part
of an automatic twin leaf door and gate system, driven
by way of an alternative current single phase motor
(with permanent capacitor) without an encoder.
VIVO-M201: operators of 230Vac, 50Hz;
VIVO-M201M: operators of 125Vac, 60Hz
General features
• Power supply (earthed):
M201: 230Vac, 50Hz; M201M: 125Vac, 60Hz
• Installation with two operators
• Common torque regulation for both operators
• Control of run by timing
• Adjustable standby time in automatic cycle
• Common opening and closing mini-push buttons
for the two operators
Notable features
Garage light (T.LG)
The garage light time can be programmed at between
3 and 120 seconds (using the T.LG power meter). Time
begins to count when the operation starts.
Flashing light
The light remains on during the opening and closing
operations.
The light goes off when the operation finishes. The light
goes off whenever operation is interrupted at an
intermediate point.
Traffic light
A traffic light can be connected if the AEPS1-001 card
is installed. Using colour lights, this will indicate the
suitability or otherwise of crossing the gate.
• Off: gate closed.
• Green light: gate open, free passage.
• Red light: gate in movement, passage forbidden.
• Flashing green light: open gate about to close in
automatic mode.
STOP pushbutton (emergency stop)
This control board allows an em ergency stop
pushbutton to be installed (STOP). This pushbutton is of
NC type (normally closed). The opening of the contact
produces the immediate halting of the gate.
40
Installation Manual
This control board is equipped with a soft stop system
which reduces speed at the end of the opening and
closing operations, in order to prevent impacts and
bangs to the gate.
It is necessary to install additional safety elements
(photocells or mechanical strips) in order to fulfil the
requirements of Standard EN 12453.
• Opening and closing safety device cable connectors
(photocells)
• Cable connectors for emergency stop pushbutton
(STOP)
• Connector for plug-in receiver
• Connector for traffic light card
• 24Vac output for peripheral connection
• Electrolock output (17Vdc)
• Adjustable lapse between leaves
Soft stop function (DIP8)
Function which reduces the speed of the leaves when
approaching the opening and stop on closings.
DIP8=ON: reduces speed
DIP8=OFF: does not reduce speed
Operation pre-warning function (DIP2)
This function delays the start of operation by three
seconds, during which time the flashing light comes on
to warn us that operation is about to begin.
DIP2=ON: 3 second warning
DIP2=OFF: no warning
Hydraulic pressure maintenance (DIP7)
Function which sends a close impulse every half an hour
as of the last operation
DIP7=ON: function activated
DIP7=OFF: function disabled
Behaviour when connecting the power
supply
With the control board now programmed, if the power
supply goes off and returns, pressing any key device will
make the control board carry out an opening operation,
regardless of the position of the leaves.