Fit accessories securely. If the machine is operated
in a holder: secure the machine well. Loss of control
can cause personal injury.
For the complete range of accessories, see
www.metabo.com or the main catalogue.
9. Repairs
Repairs to electrical tools must ONLY be
carried out by qualified electricians!
A defective mains cable must be replaced only with
a special, original mains cable from Metabo
available from the Metabo service.
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. For
addresses see www.metabo.com.
You can download a list of spare parts from
www.metabo.com.
10. Environmental Protection
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
11. Technical Specifications
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
P
= Rated input power
1
P
= Power output
2
n
= Idle speed
0
n
= Speed at rated load
1
s max. = maximum impact rate
ø max. = maximum drill diameter
G
= Drill spindle thread
H
= Drill spindle with hexagon socket
m
= Weight without mains cable
D
= Collar diameter
The technical specifications quoted are subject to
tolerances (in compliance with relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. The actual load may be higher
or lower depending on operating conditions, the
condition of the power tool or the accessories used.
Please allow for breaks and periods when the load
is lower for assessment purposes. Arrange
protective measures for the user, such as
organisational measures based on the adjusted
estimates.
Vibration total value (vector sum of three directions)
determined in accordance with EN 62841:
a
= Vibration emission value (impact drilling
h, ID
into concrete)
a
= Vibration emission value
h, D
(Drilling in metal)
K
,K
=Uncertainty (vibration)
h,ID
h,D
Typical A-effective perceived sound levels:
L
= sound-pressure level
pa
L
= Acoustic power level
WA
K
, K
= Uncertainty
pA
WA
The noise level can exceed 80 dB(A) during
operation.
Wear ear protectors!
ENGLISH en
9