Buffalo CU489 Manual De Instrucciones página 8

Maguina de filtracion de aceite para freidoras comercial
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
EN
Troubleshooting
If you find any faults not listed here, please Call Buffalo agent or qualified technician.
Fault
Power indicator (red LED)
remains inactive
Unit is very noisy during
operation
Power indicator (red LED)
flashes and an acoustic
signal sounds
Power indicator (red LED)
and filter indicator
(green LED) flash and an
acoustic signal sounds
Appliance does not start
Line fuse /Ground fault
circuit fuse (GFCI)
blow-out
Low filtration
performance
Oil splashed sideways
and /or at the back of the
pump-filter unit
8
CU489_ML_A5_v2_20231010.indb 8
Probable Cause
Power cord not plugged in
Power cord defective
Device defective
Star handles are loose
Rotor defective
Rotor scratches on the fryer
Over-temperature
Appliance is at an angle of
more than 17°
Strong vibrations caused by
Filter not closed properly
Strong vibrations caused by
damaged rotating parts
Control unit defective
Power cord or other electrical
components defective
Rotor defective /blocked
Circuit overloaded
Particle filter is full
Pump-filter unit clogged
Filter paper not inserted
properly
Motor defective
Particle filter full
Too much space between
filter cover and pump-filter
unit
Filter paper not inserted
overlapping
Solution
Plug in the appliance
Call Buffalo agent or qualified
technician
Call Buffalo agent or qualified
technician
Tighten star handles
Call Buffalo agent or qualified
technician
Change the position of the appliance
in the deep fryer
Let the appliance cool down.
Place the appliance in a cool place
Check position of the appliance in the
fryer
Switch off the machine and close
filter properly
Please contact service
Call Buffalo agent or qualified
technician
Call Buffalo agent or qualified
technician
Call Buffalo agent or qualified
technician
Change socket/circuit
Change particle filter
Empty pump-filter unit; Boil out to
remove heavy dirt
Insert filter as described
Call Buffalo agent or qualified
technician
Change particle filter
Please contact service
Insert particle filter as described
2023/10/10 17:31:34