b. Filter lifetime indicator
Status
More than 14 days
Less than 14 days
The �lter has reached the
end of life and should be
replaced immediately
c. Overtime protection
If the system is constantly working for 30 minutes, the system will go into protec-
tion mode and shut down. Meanwhile, the operation status indicator �ashes in red,
and you will hear 15 beeps. Unplug the system, wait for 1 minute, and plug in again
to shoot the trouble.
d. Auto-�ush
- The system �ushes automatically for 18 seconds when it is powered up.
- The system �ushes automatically for 6 seconds when it has operated for 5 minutes.
- The system �ushes automatically for 30 seconds when it has been in standby for
72 hours.
e. Flush button
You may manually �ush the system by pressing the �ush button when the system is
on standby mode. During the �ushing, press the �ush button again to stop it.
f. Reset button
To reset the �lter lifetime, long press the reset button for 3 seconds. You will hear a
beep, and the indicator of RO �lter lifetime �ashes in blue. Short press the reset
button again to select the �lter that needs to be reset.
When the indicator of the selected �lter �ashes, long press the reset button for 5
seconds. You will hear a beep, and the indicator of the selected �lter will be in
constant blue light after �ashing twice. This means the �lter lifetime has been reset
successfully.
Indicator
Constant blue ligh
Flashing red light
Constant red light
12
Sound alert
N/A
There will be beeps for 6
seconds after the faucet is
turned on,reminding you to
replace the �lter.
There will be beeps whenever
the faucet is turned on,
reminding you to replace the �lter.