Never ground yourself when taking electrical measurements.
Connect the black common lead to ground or neutral before applying the
red test lead to voltage. Disconnect the red test lead from the voltage fi rst.
Always work with a partner.
When using the probes, keep fi ngers as far behind the probe tips as
possible.
Instrument - Description
>605V
Feature Callouts
1. Inputs - for inserting test leads.
2. Display
• AUTO – indicates autoranging mode.
LOCK – indicates a test lock for the next time the TEST
button is depressed.
• ZERO – indicates test leads have been nulled.
– indicates auto power off (APO) occurs 15 minutes after
last button is depressed. To defeat APO, press the LOCK key.
3
- indicates batteries should be replaced to avoid false
+
readings.
• Analog Bar Graph – simulates an analog needle movement.
– indicates when insulation test is active.
MKΩ
– measurement units.
V Ω
3. Functions
• VAC – AC voltage from 0.1 – 600.0V.
• VDC – DC voltage from 0.1 – 600.0V.
1
• Ω /
) – Ohms and audible continuity from 0.1 – 199.9.
)
)
• Lo Ω – Ohms from 0.01 – 19.99 Ω.
• 250V/500V/1000V /M Ω – Insulation test voltages / range:
0.001 – 4000M Ω.
4. Buttons
– turns tester's power on/off.
2
– defeats APO and sets time period while in insulation
LOCK
testing mode.
ZERO
– turns backlight on for 30 seconds and nulls the test leads
while in ohms or Lo ohms mode.
– starts insulation testing.
TEST
– selects functions in a counter-clockwise direction.
– selects functions in a clockwise direction.
3
4
4