Emerson AVENTICS ED02 Instrucciones De Servicio página 15

Válvula reguladora de presión
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
1 About this documentation
1.1 Documentation validity
This documentation applies to the following Pressure regulators.
Material number
Output pressure
R414014403
-1 to +1 bar
R414014404
-1 to +1 bar
R414014405
-1 to +1 bar
R414014406
0 to 0.3 bar
R414014407
0 to 0.3 bar
R414014408
0 to 0.3 bar
R414014449
0 to 0.3 bar
R414014450
0 to 0.3 bar
R414014451
0 to 0.3 bar
R414014409
0 to 1 bar
R414014410
0 to 1 bar
R414014411
0 to 1 bar
R414014452
0 to 1 bar
R414014453
0 to 1 bar
R414014454
0 to 1 bar
R414014412
0 to 2 bar
R414014413
0 to 2 bar
R414014414
0 to 2 bar
R414014455
0 to 2 bar
R414014456
0 to 2 bar
R414014457
0 to 2 bar
R414014415
0 to 6 bar
R414014416
0 to 6 bar
R414014417
0 to 6 bar
R414014458
0 to 6 bar
R414014459
0 to 6 bar
R414014460
0 to 6 bar
R414014418
0 to 10 bar
R414014419
0 to 10 bar
R414014420
0 to 10 bar
R414014461
0 to 10 bar
R414014462
0 - 10 bar
R414014463
0 - 10 bar
R414001197
0 to –1 bar
R414001198
–1 to +1 bar
R414001199
–1 to +1 bar
R414001200
–1 to +1 bar
R414002405
0 to 0.3 bar
R414002406
0 to 0.3 bar
R414002407
0 to 0.3 bar
R414002408
0 to 0.3 bar
R414003364
0 to 1 bar
R414003365
0 to 1 bar
R414004660
0 to 1 bar
R414003879
0 to 1 bar
R414003370
0 to 2 bar
R414003371
0 to 2 bar
R414003372
0 to 2 bar
R414003373
0 to 2 bar
R414002400
0 to 6 bar
R414002401
0 to 6 bar
R414002402
0 to 6 bar
R414002403
0 to 6 bar
R414002410
0 to 10 bar
R414002411
0 to 10 bar
R414002412
0 to 10 bar
1) To supply a set point potentiometer
AVENTICS™ ED02 | R414002573-BAL-001-AG | English
Set point
Actual value
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
10 V constant
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
10 V constant
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
10 V constant
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
10 V constant
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
10 V constant
If you do not find your part number in the table, your device is custom-made. In
this case, the technical data will be provided to you (see back cover for contact
data).
This documentation is intended for installers, operators, and system owners. It
contains important information on the safe and appropriate assembly, operation,
and maintenance of the ED02 pressure regulator and how to remedy simple mal-
functions yourself.
1.2 Required documentation
The ED02 pressure regulator is a system component. Also observe
• the instructions for the other system components,
• the system documentation from the system manufacturer.
1.3 Presentation of information
1.3.1 Warnings
In this documentation, there are warning notes before the steps whenever there
is a risk of personal injury or damage to equipment. The measures described to
avoid these hazards must be followed.
Safety instructions are set out as follows:
Structure of warnings
Hazard type and source
Consequences of non-observance
Precautions
u
Meaning of the signal words
Immediate danger to the life and health of persons.
Failure to observe these notices will result in serious health consequences, in-
cluding death.
Possible danger to the life and health of persons.
Failure to observe these notices can result in serious health consequences, in-
cluding death.
Possible dangerous situation.
Failure to observe these notices may result in minor injuries or damage to
property.
Possibility of damage to property or malfunction.
1)
Failure to observe these notices may result in damage to property or malfunc-
tions, but not in personal injury.
1.3.2 Symbols
1)
Recommendation for the optimum use of our products.
Observe this information to ensure the smoothest possible operation.
1)
1.3.3 Abbreviations
This documentation uses the following abbreviations:
Abbreviation
Meaning
1)
ED02
E = Electropneumatic pressure regulator,
D = Directly controlled
02 = Nominal width 2
DC
Direct current
1)
WS
wrench size
SIGNAL WORD
DANGER
WARNING
CAUTION
NOTICE
15
loading