klover DUAL AIR Instrucciones Para La Instalación, El Uso Y El Mantenimiento página 78

Estufas de pellet/lena pellet
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 128
EN
11.11 REMOVING THE FIRE BRICKS
l
It is advisable to perform beforehand the
of the combustion
chamber" operation.
l
Recommended cleaning frequency: consult the para-
graph
"Scheduled
maintenance".
To dispose of any ash, consult the paragraph
disposal".
TOOLS TO BE USED; ash vacuum device equipped
with a fine-mesh filter in order to prevent part of the
ash from being blown into the room.
a
Handle the refractory bricks very carefully as they do
not withstand impacts.
11.11.1 REMOVAL OF THE REFRACTORY BRICKS -
PELLET SIDE
d
The unburned pellets must NOT be poured into the
tank.
To dismantle and replace the refractory bricks, proceed as follows:
- open the door of the appliance, consult the paragraph
door"
- remove the flame separator and the brazier
36
- remove the pairs of side fire bricks (1) - (2) first and then the central
one (3).
"Cleaning
2
"Ash
11.11.2 REMOVAL OF THE REFRACTORY BRICKS - WOOD
SIDE
To dismantle and replace the refractory bricks, proceed as follows:
- open the door of the appliance, consult the paragraph
door"
- pull the locking profile (1) towards you to release the top refractory
"Opening the
brick (2) and remove it; during the operation, support the side bricks
(3) to avoid them falling.
Fig. 47
1
3
2
3
CS.DLA.IST_EN_Rev. 1.0_11-23
MAINTENANCE
Fig. 48
"Opening the
1
Fig. 49
loading