10. INSTALLATION
1. Location
Install the compressor in a covered area, well ventilated and free of dust, gases, toxic gases, chemical products humidity or any other kind
of pollution.
The noise level of the compressor, measured in an open space, may rise considerably if the installation place is surrounded by walls that
reflect sound. This equipment must not be installed where inadvertent people may have access to. Observe this aspect when choosing the
best place for installation.
The maximum ambient temperature recommended for operation is 104°F (40°C). If the ambient temperature is higher, exhaust fans or other
means to lower the temperature must be provided. The lower the ambient temperature is better for compressor working conditions. The
presence of contaminants (dust, fibers, chemical products, etc.) suspended in the air, can cause premature saturation of the air filter and
heat exchanger (See Preventive Maintenance section).
It is important to emphasize that chemical products can be absorbed by the air filter, contaminating the oil and causing lubrication problems,
compromising the quality of compressed air as well as damaging the external and/or peripheral components of the compressor, be they
mechanical, electrical or electronic.
In order to reduce the noise level of the compressor, an acoustic project should be adopted.
ATTENTION
2. Foundation / Packaging
Install the compressor removing the accessory for transportation (base) and place it on a leveled concrete floor. It is not necessary to install
vibration dampers in the compressor Scroll. It is just in case of doubt regarding the installation of vibration dampers, contact the nearest
SCHULZ AUTHORIZED DEALER. Do not fasten the compressor on the floor.
3. Positioning and dimensions of the compressor (installation)
Observe the distance indicated in Figure 7.1, from any obstacle in order to facilitate maintenance jobs.
4 Electrical installations
Refer to a specialized technician to evaluate the general conditions of the power line and select the proper power supply and protection
devices. the instructions contained in this manual must be followed, see table 7.2.
ATTENTION
must be followed.
ATTENTION
of load. The power line must not present voltage variation over 10%. The voltage drop generated by the start peak must not be over 10%.
The electric panel of the compressor has a terminal block for adaptation of remote activation.
The start switch features an overload relay for protection of the motor of the compressor.
For your safety, the frame of the compressor must be properly connected to the ground wire.
The electric power supply must be protected with fuses, installed close to the compressor (see Table 7.2).
Do not install the compressor in chemically contaminated areas.
As a suggestion the power supply cables should be dimensioned, taking into account the capacity of the
start switch of the compressor and the distance of the power source (See Table 10.1), but the local legislation
Check the capacity of the transformer to stand the installed power rating of the compressor. If you do not
have your own transformer, you must evaluate if the mains and principal circuit breakers hold the increase