5. Air Distribution
The compressor is supplied from factory with service valve in the air outlet to the system with female thread (according to the table of
technical features).
Do not use connection with reduction in the outlet of the compressor and do not install undersized line filter(s), so as not to cause load loss
near the source of air production. Whenever possible, install "Y" instead of "T" connections and long-radius curves.
The electric motor is equipped with sensors for overload protection.
For versions of direct air compressors installed in short systems, it is always recommended to install an air tank.
A good project of a compressed air system always establishes the installation of a tank in order to absorb pulsations produced by the sudden
consumption, collect condensate and strategically keep a spare supply for occasional consumption peaks.
We recommend installing, in the air outlet, a service line with a hose and an air blow gun for cleaning the radiator and other jobs that require
local compressed air.