INSTALLATION INSTRUCTIONS
WARNING
Electrical Shock Hazard
When using any electrical device (such as a power
drill) during installation, be sure the device is battery
powered, double insulated or grounded in a manner that
will prevent the hazard of electric shock.
CAUTION:
Connect to potable water supply only.
IQVWDOO WKH VKXWRç valve on the nearest frequently used
drinking water line.
1. SHUT OFF THE MAIN WATER SUPPLY
Turn on the nearest faucet to relieve the pressure on the
line.
2. CHOOSE THE VALVE LOCATION
Choose a location for the valve that is
easily accessible. It is best to connect
into the side of a vertical water pipe.
When it is necessary to connect into
a horizontal water pipe, make the
connection to the top or side, rather
than at the bottom, to avoid drawing
from the water pipe.
3. DRILL THE HOLE FOR THE VALVE
Drill a ¼ in. hole in the water
pipe using a sharp bit. Remove
any burrs resulting from drilling
the hole in the pipe. Be careful
not to allow water to drain into
the drill. Failure to drill a ¼ in.
hole may result in reduced ice
production or smaller cubes.
NOTE: The hookup line cannot be white, plastic
tubing. Licensed plumbers must use only copper
tubing (NDA tubing #49595 or #49599) or Cross
Link Polyethylene (PEX) tubing.
4. FASTEN THE SHUTOFF VALVE
Fasten the
valve to the cold water pipe with
the pipe clamp.
Pipe Clamp
Saddle-Type
Valve
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegal and their use is not permitted in Massachusetts.
Consult with your licensed plumber.
5. TIGHTEN THE PIPE CLAMP
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE: Do not overtighten clamp or you may crush the
tubing.
Clamp Screw
6. ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
as close to the wall as possible.
NOTE: Be sure there is
any sediment
8 feet coiled into 3 turns of about 10 in. diameter) to
allow the refrigerator to move out from the wall after
installation.
7. CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve) for the
copper tubing onto the end of the tubing and connect
it to the
inserted into the valve. Tighten the compression nut
securely.
Saddle-Type
Packing Nut
Outlet Valve
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegal and their use is not permitted in
Massachusetts. Consult with your licensed plumber.
Vertical Cold
Water Pipe
29
CONNECTING THE WATER LINE
Pipe Clamp
(behind the refrigerator or adjacent base cabinet)
valve. Make sure the tubing is fully
Valve
Washer
Inlet End
extra tubing (about
Compression Nut
Ferrule (sleeve)
loading

Este manual también es adecuado para:

795.6803 serie795.7803 serie